Product: | Toggle switch |
Manufacturer: | Nidec Copal |
Features: | 1. Contacts : Silver or gold. |
2. Epoxy resin case : UL94V-0 self-extinguishing epoxy. | |
3. Actuator styles : Over 30 actuator variations. | |
4. Insulation between terminal and ground : 4 mm minimum. | |
5. Prevention of flux entry The epoxy resin seal on bottom of the switch helps prevent the entry of solder and flux. | |
6. Insulation barrier : Insulation barrier design between poles helps prevent short-circuiting between poles ensuring high reliability. | |
7. UL Recognized product File No.E432759 | |
8. CSA Certified product File No.LR38341 |
Contact
Specifications | |
Packaging method: | Bag |
Installation type: | Panel |
Operating temp: | -30℃~85℃ |
Ampacity: | Silver Contact: 6A/3A/4A Gold Contact: 6A/3A /25mA |
Rated voltage: | Silver Contact: AC125V/AC250V /DC30V Gold Contact: AC125V/AC250V/DC20V |
Size (mm) (L*W*H): |
8x13x9 13x13x9 17.8x13x11.3 22.6x13x11.3 |
note | For further information, please contact:+886-3-4266335 |
Additional info | |
Terminal type: | Soldering/Through hole,Right angle/Through hole,Right angle,Vertical |
Circuit: | 1~4PDT |
Feature: |
Circle shape |
Rating Max.: | Silver Contact:AC125V 6A AC250V 3A DC30V 4A Gold Contact:AC125V 6A AC250V 3A DC20V 25mA |
---|---|
Initial contact resistance: | Silver Contact:10mΩ Max. (DC2~4V 1A) Gold Contact:20mΩ Max. (AC200μV 1.5mA) |
Initial dielectric strength: | AC1500V 1minute |
Initial insulation resistance: | 1000MΩMin. ( DC500V) |
Electrical life: | Alternate type:50,000cycles Momentary type:25,000cycles |
Operating temperature range: | -30~+85℃ |
Storage temperature range: | -40~+85℃ |
Soldering Specifications
- Manual soldering/Device :Solder iron ①420℃ Max. 3 sec. Max.
- Auto soldering/275℃ Max. 6 sec. Max.
- The above-stated soldering conditions shall apply only to switches with straight terminals. Auto soldering is not possible with right-angle terminals. Switches with right-angle terminals should be soldered manually according to the conditions specifi ed in (1) above.
- When soldering two or more terminals to the common land, use the solder resist to isolate the terminals.
Flux Cleaning
- Solvent : Fluorine or Alcohol type.
- 8A/B/C/D/E/F/J series are not washable. To wash the PC board, clean the soldering surface of the PC board with a brush so that the switch is not exposed to the cleaning solution.
- Cleaning after soldering should be done after the terminal temperature falls to 90℃ or below, or after leaving the switch for fi ve minutes or longer at room temperature.
Mounting
- Do not bend the terminals before mounting the switch on the PC board.
- After mounting the switch, do not place the device in such a way that the device weight will be applied on to the actuator of the switch.
- For switches with straight terminals, solder the switch on the PC board after fi xing the switch on the panel with a nut.
Back