Product: | Pressure transducer with amp. PA-100 |
Manufacturer: | Nidec Copal |
Features: | 1. Covers low pressure range. |
2. Buit-in a compact amplifier circuit. | |
3. Measures differential pressure. |
Contact
Specifications | |
Packaging method: | Bag |
Installation type: | Please refer to the product spec |
Operating temp: | -20℃ ~ 70℃ |
Ampacity: | Please refer to the product spec |
Rated voltage: | Please refer to the product spec |
Size (mm) (L*W*H): |
Please see info below |
note | For further information, please contact:+886-3-4266335 |
Compensated temp. range: | 0 ~ 50°C |
Operating humidity: | 35 ~ 85%RH(No condensation) |
Storage temp.: | − 20 ~ 80(Atmospheric pressure, humidity 65 %RH maximum) |
Pressure medium: | Non-corrosive gases |
Insulation resistance: | 100 MΩ Min. (50 V DC) |
Dielectric strength: | 50 V AC, 60 s(Leakage current 1 mA maximum) |
Pressure port: | φ 2.5mm |
Net weight: | Approx. 8g |
Supply voltage: | 5 ± 10 %V DC |
Consumption current: | 5 mA maximum |
Model Number Designation | |
PA-100- | 100D-S |
Series name | Rated pressure range |
100D-S: 0 ~ 1 kPa {102 mmH2O} 200D-S: 0 ~ 2 kPa {204 mmH2O} 500D-S: 0 ~ 5 kPa {510 mmH2O} 100D-W:− 1 ~ 1 kPa {± 102 mmH2O} 200D-W:− 2 ~ 2 kPa {± 204 mmH2O} 500D-W:− 5 ~ 5 kPa {± 510 mmH2O} |
Environment Characteristics | ||
Test item | Test conditions (At 25 ± 5 °C) | Permissible change |
Vibration | 10 ~ 500 Hz, 1.5 mm maximum/49 m/s2 , 3 directions for 2 hours each |
Zero voltage/Span voltage: ± 2 %F.S. (100D/200D) maximum and ± 1 %F.S. (500D) each |
Shock | 490 m/s2, 3 directions for 3 times each | |
Pressure cycling | 0 ~ Rated pressure, 106 cycles | |
Moisture resistance | 40 °C, 90 ~ 95 %RH, 240 hrs. |
Outline Dimensions
Internal Circuit Diagram
Back